Copper in Brass: Ammonia Complex Method
To determine % copper in brass by dissolving the alloy and measuring [Cu(NH3)4]²⁺ at 610 nm.
Theoretical Foundations
Brass (Cu-Zn alloy) dissolves in nitric acid; zinc stays colourless in ammonia while copper forms the deep-blue tetraammine complex (610 nm). After dilution into the calibration range, absorbance gives copper mass and hence % Cu in the alloy (typically 60-70% for common brass).
Required Apparatus & Chemicals
Laboratory Apparatus
- UV-Vis spectrophotometer
- Volumetric flasks 250, 100 mL
- Hot plate
- Pipettes
- Cuvettes
- Fume cupboard
Chemical Reagents
- Brass sample (0.0500 g)
- Nitric acid (conc.)
- CuSO4 standard (100 mg L⁻¹)
- Concentrated ammonia
Step-by-Step Practical Procedure
- Dissolve 0.0500 g brass in 5 mL conc. HNO3 in a fume cupboard; dilute to 250 mL.
- Prepare Cu standards 0-8 mg L⁻¹ with 10 mL conc. NH3 per 100 mL.
- Dilute 10.00 mL of the brass solution to 100 mL with ammonia added.
- Zero at 610 nm with the ammonia blank.
- Read standards and sample.
- Calculate % Cu in the brass.
Observations & Expected Results
Brass solution turns deep blue in ammonia; zinc contributes no colour; calibration linear at 610 nm (slope ≈ 0.0663 A·L mg⁻¹).
Worked Stoichiometric Calculations
Problem: 0.0500 g brass to 250 mL; 10.00 mL diluted to 100 mL gives A = 0.820 (slope 0.0663 A·L mg⁻¹). Find % Cu.
Working: c(measured) = 0.820/0.0663 = 12.37 mg L⁻¹. Stock = 123.7 mg L⁻¹. In 0.250 L: 30.9 mg Cu. %Cu = 30.9/50.0 × 100 = 61.8%.
Safety Precautions & Hazard Control
- Dissolve brass only in a fume cupboard (nitrogen dioxide fumes).
- Dissolve completely; undissolved metal biases the result low.
- Add the same ammonia volume to every flask.
- Lead in some brasses precipitates as sulfate; filter if turbid.
Waste Disposal Protocol
Ammoniacal copper/zinc/nitrate waste to the aqueous heavy-metal waste bottle.
Viva Voce Oral Defense Questions & Answers
Q: Why does zinc not interfere?
A: Zn²⁺ forms a colourless ammine complex, so at 610 nm only the blue copper complex absorbs.
Q: Why dissolve in nitric acid rather than HCl?
A: Nitric acid oxidises and dissolves copper alloys cleanly; HCl alone cannot oxidise copper metal.
Q: How would you determine zinc in the same solution?
A: By a separate method, e.g. EDTA titration or dithizone spectrophotometry, since zinc is invisible at 610 nm.