Lead in Battery Paste as Lead Sulfate
Determine lead in lead-acid battery paste by precipitation as PbSO4.
Theoretical Foundations
Battery paste (PbO, PbO2, PbSO4 mixture) is digested in acid; all lead is brought into solution as Pb2+ (PbO2 is reduced with H2O2 or hydroxylamine). Adding sulfate precipitates lead sulfate: Pb2+ + SO4 2- → PbSO4(s). PbSO4 is the stoichiometric weighing form after drying at 150 C (it decomposes on strong ignition). GF for lead = M_Pb/M_PbSO4 = 207.2/303.26 = 0.6832.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 250 mL beaker
- Hot plate
- Fume cupboard
- Sintered-glass crucible
- Oven at 150 C
- Desiccator
- Lead PPE (gloves, no dust inhalation)
Chemical Reagents
- Battery paste sample
- Nitric acid, dilute
- Hydrogen peroxide, 3%
- Sulfuric acid, dilute (1 M)
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 1.0 g of paste (avoid inhaling dust; wear gloves).
- Digest with 15 mL dilute HNO3 plus 5 mL 3% H2O2 to reduce PbO2, warming gently.
- Dilute to 150 mL; filter off any insoluble residue.
- Heat to near boiling; add 10 mL 1 M H2SO4 slowly with stirring.
- Digest warm 30 minutes; filter through a weighed sintered-glass crucible.
- Wash with dilute H2SO4 then water; dry at 150 C to constant mass.
- Weigh PbSO4; calculate % Pb.
Observations & Expected Results
Dark paste dissolves to a colourless solution; white heavy PbSO4 precipitates, typically about 0.85 g from 1 g paste.
Worked Stoichiometric Calculations
Problem: 1.000 g of battery paste gave 0.8520 g PbSO4. Calculate % Pb. (GF_Pb = 0.6832)
Working: Mass Pb = 0.8520 × 0.6832 = 0.5821 g. % Pb = (0.5821/1.000) × 100 = 58.21%.
Safety Precautions & Hazard Control
- Lead compounds are toxic: gloves, no dust inhalation, fume cupboard.
- Reduce all PbO2 or it stays undissolved and is lost.
- Dry at 150 C; PbSO4 decomposes if ignited strongly.
Waste Disposal Protocol
All lead residues and filtrates to dedicated lead waste; never down the drain.
Viva Voce Oral Defense Questions & Answers
Q: Why add H2O2 during digestion?
A: To reduce insoluble PbO2 to soluble Pb2+ so that all lead enters the solution for precipitation.
Q: Why not ignite PbSO4?
A: It decomposes at high temperature (losing SO3), so it is only dried at 150 C as the weighing form.