Zinc as Zinc Pyrophosphate
Determine zinc in an alloy by precipitation as ZnNH4PO4 and ignition to Zn2P2O7.
Theoretical Foundations
Zinc is precipitated analogously to magnesium: Zn2+ + NH4+ + HPO4 2- → ZnNH4PO4(s) + H+. Ignition gives zinc pyrophosphate: 2ZnNH4PO4 → Zn2P2O7 + 2NH3 + H2O. The gravimetric factor for zinc is 2 × M_Zn/M_Zn2P2O7 = 130.76/304.71 = 0.4291. Copper and iron must be removed beforehand as they also form phosphates.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 400 mL beaker
- Hot plate
- Ashless filter paper
- Porcelain crucible
- Muffle furnace
- Desiccator
Chemical Reagents
- Zinc alloy sample (Cu/Fe removed or absent)
- Hydrochloric acid, dilute
- Diammonium hydrogen phosphate solution, 10%
- Ammonia solution, concentrated and dilute
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.5 g alloy; dissolve in 15 mL dilute HCl.
- Remove interfering ions (precipitate Cu with H2S or Fe with ammonia) and filter.
- Dilute the filtrate to 150 mL; add 15 mL 10% (NH4)2HPO4.
- Add concentrated ammonia with stirring to strong alkalinity; stand 4 hours.
- Filter through ashless paper; wash with dilute ammonia.
- Ignite at 900 C to constant mass; weigh Zn2P2O7 and calculate % Zn.
Observations & Expected Results
White crystalline precipitate; white Zn2P2O7, typically about 0.31 g from 0.5 g alloy.
Worked Stoichiometric Calculations
Problem: 0.5000 g of alloy gave 0.3120 g Zn2P2O7. Calculate % Zn. (GF_Zn = 0.4291)
Working: Mass Zn = 0.3120 × 0.4291 = 0.1339 g. % Zn = (0.1339/0.5000) × 100 = 26.78%.
Safety Precautions & Hazard Control
- Remove Cu2+ and Fe3+ first; both give insoluble phosphates.
- Stand long enough for complete crystallisation.
- Ignite to constant mass at 900 C.
Waste Disposal Protocol
Ammoniacal phosphate filtrates to aqueous waste.
Viva Voce Oral Defense Questions & Answers
Q: Which ions interfere and why?
A: Cu2+, Fe3+, Al3+ and Ca2+ form sparingly soluble phosphates under the ammoniacal conditions and would be weighed as zinc.
Q: Compare this with the magnesium pyrophosphate method.
A: The chemistry is identical (MNH4PO4 → M2P2O7); only the gravimetric factor differs, showing how one procedure serves several analytes.