CHEMVEN

Constant Current versus Controlled Potential Deposition

Show that controlled-potential deposition separates copper from nickel, while constant current does not.

Level: UniversitySafety: Needs supervisionTime: 3 h
Aim of Experiment: Show that controlled-potential deposition separates copper from nickel, while constant current does not.

Theoretical Foundations

Cu2+/Cu (+0.34 V) and Ni2+/Ni (−0.25 V) have well-separated reduction potentials. At constant current the cathode potential drifts negative as copper depletes, eventually depositing nickel too. With a potentiostat holding the cathode at −0.30 V vs SCE, only copper deposits (Cu2+ + 2e- → Cu) while Ni2+ stays in solution — demonstrating selective electrogravimetry.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Analytical balance
  • Platinum electrodes
  • Potentiostat with reference electrode (SCE)
  • DC power supply
  • Two beakers
  • Oven
  • Desiccator

Chemical Reagents

  • Cu-Ni standard solution (50.0% Cu)
  • Sulfuric acid, dilute
  • Distilled water
  • Ethanol

Step-by-Step Practical Procedure

  1. Place identical aliquots of Cu-Ni solution in two cells; weigh two cathodes.
  2. Cell A: electrolyse at constant 2 A for 45 minutes.
  3. Cell B: electrolyse at controlled −0.30 V vs SCE until the current falls to background.
  4. Wash (current/potential maintained), dry and weigh both cathodes.
  5. Calculate apparent % Cu for each and compare with the true 50.0%.

Observations & Expected Results

Deposit A is slightly off-colour (nickel codeposited); deposit B is pure pink copper.

Worked Stoichiometric Calculations

Problem: 0.5000 g alloy equivalent per aliquot. Constant current gave 0.3015 g deposit; controlled potential gave 0.2490 g. Calculate apparent % Cu for each (true = 50.0%).

Working: Constant current: (0.3015/0.5000) × 100 = 60.3% (high — nickel codeposited). Controlled potential: (0.2490/0.5000) × 100 = 49.8% ≈ true value. Potential control achieves the separation.

Safety Precautions & Hazard Control

  • Position the reference electrode close to the cathode.
  • Let the controlled-potential run reach background current for completeness.
  • Do not let the constant-current cell run so long that the deposit burns.

Waste Disposal Protocol

Electrolytes to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does constant current eventually deposit nickel?

A: As Cu2+ depletes, maintaining the fixed current forces the cathode potential more negative until Ni2+ reduction can sustain it — selectivity is lost.

Q: What is the role of the reference electrode?

A: It lets the potentiostat hold the working electrode at a fixed potential, so only species reducible at that potential deposit.

← Back to Experiments Directory