Magnesium in Magnalium Alloy
Determine magnesium in a magnalium (Al-Mg) alloy after removing aluminium.
Theoretical Foundations
The alloy is dissolved in HCl; aluminium is precipitated with ammonia as Al(OH)3 and filtered off (magnesium stays soluble). Magnesium is then precipitated: Mg2+ + NH4+ + HPO4 2- → MgNH4PO4(s) + H+, ignited to Mg2P2O7 (GF = 0.2184). Magnalium typically contains 5-30% Mg.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 400 mL beaker
- Hot plate
- Ashless filter paper
- Porcelain crucible
- Muffle furnace
- Desiccator
Chemical Reagents
- Magnalium alloy sample
- Hydrochloric acid, dilute
- Ammonia solution, dilute and concentrated
- Diammonium hydrogen phosphate solution, 10%
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.4 g of alloy; dissolve in 15 mL dilute HCl with warming.
- Dilute to 200 mL; add dilute ammonia to precipitate Al(OH)3 (just alkaline); filter off.
- Acidify the filtrate slightly; add 15 mL 10% (NH4)2HPO4.
- Add concentrated ammonia with stirring to strong alkalinity plus excess; stand 4 hours.
- Filter, wash with dilute ammonia, ignite at 1000 C to constant mass.
- Weigh Mg2P2O7; calculate % Mg.
Observations & Expected Results
Gelatinous Al(OH)3 filtered off; white crystalline magnesium precipitate; white Mg2P2O7, typically about 0.165 g from 0.4 g alloy.
Worked Stoichiometric Calculations
Problem: 0.4000 g of magnalium gave 0.1650 g Mg2P2O7. Calculate % Mg.
Working: Mass Mg = 0.1650 × 0.2184 = 0.03604 g. % Mg = (0.03604/0.4000) × 100 = 9.01%.
Safety Precautions & Hazard Control
- Remove aluminium quantitatively or it contaminates the phosphate precipitate.
- Do not precipitate Al(OH)3 with a large excess of ammonia (it redissolves).
- Stand the magnesium precipitate long enough.
Waste Disposal Protocol
Acidic/alkaline metal filtrates neutralised; residues to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is aluminium removed before precipitating magnesium?
A: Al3+ would precipitate as AlPO4 with the phosphate reagent, contaminating the MgNH4PO4 and giving high results.
Q: Why does Al(OH)3 redissolve in excess ammonia only slightly, unlike with NaOH?
A: Al(OH)3 is amphoteric toward strong base (forming aluminate) but only very slightly soluble in ammonia, so a small excess of ammonia is safe.