CHEMVEN

Trace Iron in Groundwater: Large-Volume Precipitation

Determine trace iron in groundwater (mg/L) by concentrating a large volume.

Level: UniversitySafety: Needs supervisionTime: 3 h
Aim of Experiment: Determine trace iron in groundwater (mg/L) by concentrating a large volume.

Theoretical Foundations

Groundwater iron (often Fe2+ from anoxic aquifers) oxidises on aeration. A 2 L sample is evaporated to concentrate the iron, oxidised to Fe3+, precipitated as Fe(OH)3 and ignited to Fe2O3 (GF = 0.6994). The drinking-water aesthetic limit for iron is 0.3 mg/L (taste and staining).

Required Apparatus & Chemicals

Laboratory Apparatus

  • 2 L measuring cylinder
  • 1 L evaporating basin
  • Hot plate
  • 400 mL beaker
  • Ashless filter paper
  • Porcelain crucible
  • Muffle furnace
  • Desiccator

Chemical Reagents

  • Groundwater sample
  • Hydrochloric acid, dilute
  • Nitric acid, concentrated
  • Ammonia solution, dilute
  • Ammonium chloride, solid
  • Distilled water

Step-by-Step Practical Procedure

  1. Measure 2.00 L of groundwater; acidify with 5 mL dilute HCl at collection to keep iron dissolved.
  2. Evaporate in the basin to about 150 mL.
  3. Transfer to a beaker; add 2 mL conc. HNO3 and warm to oxidise Fe2+.
  4. Add NH4Cl, precipitate Fe(OH)3 with dilute ammonia.
  5. Filter, wash, ignite at 850 C to constant mass; weigh Fe2O3.
  6. Calculate iron in mg/L.

Observations & Expected Results

Clear water leaves a faint brown residue on evaporation; tiny reddish Fe2O3 residue after ignition, typically a few milligrams.

Worked Stoichiometric Calculations

Problem: 2.00 L of groundwater gave 0.0042 g Fe2O3. Calculate iron in mg/L.

Working: Mass Fe = 0.0042 × 0.6994 = 0.002938 g = 2.938 mg. Concentration = 2.938 mg / 2.00 L = 1.47 mg/L Fe — above the 0.3 mg/L aesthetic limit; treatment needed.

Safety Precautions & Hazard Control

  • Acidify the sample at collection or Fe2+ oxidises and adsorbs on the container walls.
  • Evaporate gently; do not bake the residue.
  • Run a blank; reagents contribute at trace levels.

Waste Disposal Protocol

Acidic filtrates neutralised.

Viva Voce Oral Defense Questions & Answers

Q: Why acidify groundwater samples for iron at collection?

A: To keep iron dissolved: at natural pH, Fe2+ oxidises to Fe3+ and precipitates as Fe(OH)3 on the container walls, which would be lost from the analysis.

Q: Why is iron limited in drinking water if it is not very toxic?

A: The 0.3 mg/L limit is aesthetic — iron causes metallic taste and red-brown staining of laundry and plumbing — rather than health-based.

← Back to Experiments Directory