CHEMVEN

pH Dependence of Ni(DMG)2 Precipitation

Show that quantitative precipitation of Ni(DMG)2 requires a slightly alkaline medium (pH 5-9).

Level: UniversitySafety: SafeTime: 3 h
Aim of Experiment: Show that quantitative precipitation of Ni(DMG)2 requires a slightly alkaline medium (pH 5-9).

Theoretical Foundations

The precipitation releases protons: Ni2+ + 2 H2DMG → Ni(HDMG)2(s) + 2H+. In acidic solution the equilibrium lies left and precipitation is incomplete; in strongly alkaline solution nickel hydroxide may form. The optimum window is pH 5-9, conveniently set with ammonia. Identical nickel aliquots precipitated at pH 3, 6 and 9 show the recovery profile.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Analytical balance
  • Three 400 mL beakers
  • Hot plate
  • pH meter or indicator paper
  • Sintered-glass crucibles
  • Oven
  • Desiccator

Chemical Reagents

  • Nickel standard solution (known mg Ni)
  • Dimethylglyoxime solution, 1% in ethanol
  • Ammonia solution, dilute
  • Hydrochloric acid, dilute
  • Distilled water

Step-by-Step Practical Procedure

  1. Pipette three identical aliquots of nickel standard (each about 0.2 g Ni equivalent... use a convenient standard) into three beakers; dilute to 150 mL.
  2. Add equal DMG solution to each at 70-80 C.
  3. Adjust beaker A to pH 3 (HCl), beaker B to pH 6, beaker C to pH 9 (ammonia).
  4. Digest all 30 minutes warm, filter through weighed crucibles, wash and dry at 150 C.
  5. Weigh the three precipitates and calculate % recovery against the theoretical mass.

Observations & Expected Results

Beaker A gives a sparse precipitate; B and C give full scarlet precipitates.

Worked Stoichiometric Calculations

Problem: 0.2000 g Ni should give 0.9843 g Ni(DMG)2. Found: pH 3 → 0.8515 g; pH 8 → 0.9810 g. Calculate each % recovery.

Working: Recovery pH 3 = (0.8515/0.9843) × 100 = 86.5%. Recovery pH 8 = (0.9810/0.9843) × 100 = 99.7%. Acid suppresses precipitation by the common H+ product; pH 8 is quantitative.

Safety Precautions & Hazard Control

  • Measure pH after digestion, as precipitation releases H+ and lowers pH.
  • Keep temperature and digestion time identical for all three.
  • Use the same DMG volume in each beaker.

Waste Disposal Protocol

Nickel filtrates to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Explain the pH effect using Le Chatelier's principle.

A: Precipitation produces 2H+ per Ni2+; high [H+] (low pH) drives the equilibrium back, leaving nickel in solution, while removing H+ with ammonia drives it to completion.

Q: Why not precipitate at pH 12?

A: Strongly alkaline conditions precipitate Ni(OH)2 alongside the chelate, contaminating the weighing form.

← Back to Experiments Directory