Purity of Potassium Chloride Fertilizer as AgCl
Determine the purity of muriate of potash (KCl) fertilizer from its chloride content.
Theoretical Foundations
Fertilizer-grade KCl dissolves completely in water. Chloride is precipitated as AgCl in nitric acid: Ag+ + Cl- → AgCl(s), GF = 0.2473. Pure KCl contains 35.45/74.55 = 47.55% Cl. Sodium chloride impurity raises the apparent chloride (NaCl is 60.66% Cl), so the result also screens for NaCl adulteration.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 400 mL beaker (foil-wrapped)
- Hot plate
- Sintered-glass crucible
- Oven
- Desiccator
Chemical Reagents
- KCl fertilizer sample
- Nitric acid, dilute
- Silver nitrate solution, 0.1 M
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.30-0.35 g of fertilizer.
- Dissolve in 200 mL water with 2 mL dilute HNO3; heat to near boiling.
- Add AgNO3 dropwise with stirring to complete precipitation plus small excess.
- Digest warm until coagulated; test supernatant.
- Filter through a weighed sintered-glass crucible, wash with dilute HNO3.
- Dry at 150 C to constant mass, cool and weigh AgCl; calculate % Cl and purity.
Observations & Expected Results
White curdy AgCl; typical mass about 0.66 g from 0.35 g fertilizer.
Worked Stoichiometric Calculations
Problem: 0.3500 g of KCl fertilizer gave 0.6655 g AgCl. Calculate % Cl and purity. (Theoretical Cl in KCl = 47.55%)
Working: Mass Cl = 0.6655 × 0.2473 = 0.1646 g. % Cl = (0.1646/0.3500) × 100 = 47.02%. Purity = (47.02/47.55) × 100 = 98.9% KCl.
Safety Precautions & Hazard Control
- Protect from light.
- Dissolve the sample fully; insoluble matter should be filtered off and the filtrate used.
- Wash the precipitate free of soluble salts.
Waste Disposal Protocol
Silver residues collected for recovery.
Viva Voce Oral Defense Questions & Answers
Q: How would NaCl adulteration show up in this assay?
A: NaCl contains 60.66% Cl versus 47.55% in KCl, so adulteration raises the apparent % Cl above the theoretical value for pure KCl.
Q: Why can't this method distinguish KCl from NaCl directly?
A: Both give AgCl; the method measures total chloride, so purity is inferred by assuming all chloride is KCl — a valid check only for essentially pure materials.