Silver in a Silver Alloy: Reverse AgCl Gravimetry
Determine silver in an alloy by dissolving it and precipitating Ag+ as AgCl.
Theoretical Foundations
The alloy is dissolved in nitric acid: 3Ag + 4HNO3 → 3AgNO3 + NO + 2H2O. Silver is then precipitated with chloride: Ag+ + Cl- → AgCl(s). This is reverse gravimetry — the analyte cation is precipitated by the anion. The gravimetric factor for silver is M_Ag/M_AgCl = 107.87/143.32 = 0.7527, conveniently large, giving a precise determination.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 250 mL beaker
- Hot plate
- Fume cupboard
- Sintered-glass crucible
- Oven
- Desiccator
Chemical Reagents
- Silver alloy sample
- Nitric acid, concentrated and dilute
- Sodium chloride solution, 10% w/v
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.4-0.5 g of alloy into a beaker.
- In a fume cupboard dissolve in 10 mL conc. HNO3 with gentle warming; evaporate to remove excess acid.
- Dilute to 200 mL, heat to near boiling in a foil-wrapped beaker.
- Add 10% NaCl solution dropwise with stirring until precipitation is complete.
- Digest warm, filter through a weighed sintered-glass crucible, wash with dilute HNO3.
- Dry at 150 C to constant mass and weigh AgCl.
Observations & Expected Results
Alloy dissolves with brown NO2 fumes; white AgCl precipitates on adding NaCl. Typical mass about 0.5 g from 0.5 g alloy.
Worked Stoichiometric Calculations
Problem: 0.5000 g of alloy gave 0.5215 g AgCl. Calculate % Ag. (GF_Ag = 0.7527)
Working: Mass Ag = 0.5215 × 0.7527 = 0.3925 g. % Ag = (0.3925/0.5000) × 100 = 78.51%.
Safety Precautions & Hazard Control
- Dissolve in a fume cupboard; nitrogen oxides are toxic.
- Protect AgCl from light throughout.
- Ensure complete dissolution; undissolved metal gives low results.
Waste Disposal Protocol
Silver residues collected for recovery; acidic solutions neutralised.
Viva Voce Oral Defense Questions & Answers
Q: Why is this called reverse gravimetry?
A: The analyte is the cation (Ag+) precipitated by an anion (Cl-), the reverse of the usual anion-by-cation precipitation.
Q: Why is the gravimetric factor for Ag in AgCl favourable?
A: At 0.7527 it is large, so weighing errors in the precipitate translate into small relative errors in the silver result.