Chloride in Table Salt: Purity of NaCl as AgCl
Determine the chloride content and purity of table salt by precipitation as silver chloride.
Theoretical Foundations
Chloride is precipitated with silver nitrate in dilute nitric acid: Ag+(aq) + Cl-(aq) → AgCl(s). Nitric acid prevents precipitation of silver oxide, carbonate and phosphate. The precipitate is curdy, coagulates on heating and is protected from light to avoid photodecomposition (2AgCl → 2Ag + Cl2). The gravimetric factor for chloride is M_Cl/M_AgCl = 35.45/143.32 = 0.2473. Pure NaCl contains 60.66% Cl.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 400 mL beakers (amber or foil-wrapped)
- Hot plate
- Sintered-glass (Gooch) crucible
- Oven at 150 C
- Desiccator
Chemical Reagents
- Table salt sample
- Silver nitrate solution, 0.1 M
- Nitric acid, dilute (2 M)
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.25-0.30 g of salt and dissolve in 200 mL water with 2 mL dilute HNO3.
- Heat to near boiling in a foil-wrapped beaker (exclude light).
- Add 0.1 M AgNO3 slowly with stirring until precipitation is complete plus 5 mL excess.
- Heat gently until the precipitate coagulates and the supernatant clears.
- Test completeness with a drop of AgNO3 on the clear supernatant.
- Filter through a weighed sintered-glass crucible; wash with very dilute HNO3 then a little water.
- Dry at 150 C to constant mass, cool in a desiccator and weigh AgCl.
Observations & Expected Results
White curdy precipitate forms, coagulating into clots on heating. Typical AgCl mass about 0.73 g from 0.30 g salt. The precipitate darkens to violet-grey if exposed to light.
Worked Stoichiometric Calculations
Problem: 0.3000 g of table salt gave 0.7350 g AgCl. Calculate % Cl and the purity as NaCl. (GF_Cl = 0.2473; Cl in NaCl = 60.66%)
Working: Mass Cl = 0.7350 × 0.2473 = 0.1818 g. % Cl = (0.1818/0.3000) × 100 = 60.59%. Purity = (60.59/60.66) × 100 = 99.9% NaCl.
Safety Precautions & Hazard Control
- Protect the precipitate from light at every stage; work under subdued light.
- Precipitate in dilute HNO3, never in neutral or ammoniacal solution.
- Do not use filter paper: AgCl is reduced by paper on ignition; use a sintered-glass crucible and dry at 150 C.
Waste Disposal Protocol
Silver-containing filtrates and residues are collected for silver recovery; never pour silver waste down the drain.
Viva Voce Oral Defense Questions & Answers
Q: Why is AgCl precipitated in nitric acid medium?
A: Dilute HNO3 keeps Ag2O, Ag2CO3 and Ag3PO4 dissolved so that only AgCl precipitates; HCl obviously cannot be used.
Q: Why must AgCl be kept in the dark?
A: Light photodecomposes it: 2AgCl → 2Ag + Cl2, turning it violet-grey and causing loss of mass.
Q: Why is a sintered-glass crucible used instead of filter paper?
A: Filter paper would reduce AgCl to metallic silver on ignition; the crucible allows drying at 150 C without reduction.