CHEMVEN

Separation of Nickel(II) and Cobalt(II) Ions in a Mixture by Paper Chromatography

To separate nickel(II) and cobalt(II) cations in an unknown mixture using ascending paper chromatography, identify separated zones via selective chromogenic visualization, and determine individual Rf values.

Level: University PracticalSafety: Fume Hood / CorrosiveTime: 90 min
Aim of Experiment: To separate nickel(II) and cobalt(II) cations in an unknown mixture using ascending paper chromatography, identify separated zones via selective chromogenic visualization, and determine individual Rf values.

Theoretical Foundations

Separation of Ni2+ and Co2+ on paper relies on differences in their chloro-complexation equilibria in acetone-hydrochloric acid mobile phase (acetone : conc. HCl : H2O 85:8:7). Cobalt(II) undergoes an octahedral-to-tetrahedral coordination change upon chloro-complexation: [Co(H2O)6]2+ (pink) + 4Cl- <=> [CoCl4]2- (deep blue) + 6H2O. The tetrahedral [CoCl4]2- complex is relatively non-polar and partitions into the mobile organic phase, traveling to Rf ≈ 0.45. Nickel(II) does not form stable tetrahedral chloro-complexes under these conditions and remains as the highly hydrated octahedral d8 cation [Ni(H2O)6]2+, adhering tightly to cellulose stationary water (Rf ≈ 0.08). When sprayed with dimethylglyoxime (DMG) in ammonia, Ni2+ forms an intense red chelate, while Co2+ forms a soluble brown complex or turns yellow-green with rubeanic acid.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Chromatographic developing chamber with ground-glass lid
  • Whatman No. 1 paper strips (15 × 5 cm)
  • Microcapillary applicators
  • Atomizer spray bottle
  • Pencil and graduated ruler
  • Fume cupboard

Chemical Reagents

  • Standard 0.1 M NiCl2 solution
  • Standard 0.1 M CoCl2 solution
  • Binary test mixture (Ni2+ + Co2+, 0.05 M each)
  • Eluent: Acetone : concentrated HCl : H2O (85:8:7 v/v/v)
  • Spray reagent: 1% Dimethylglyoxime in ethanol
  • Concentrated ammonia solution (28% NH3)

Step-by-Step Practical Procedure

  1. Line the developing jar with filter paper moistened with eluent and add 20 mL of acetone-HCl-H2O solvent; cover and equilibrate for 30 min.
  2. Draw a pencil baseline 2.0 cm from the bottom of a 15 × 5 cm Whatman No. 1 paper strip.
  3. Apply 2 uL of standard Ni2+, standard Co2+, and the binary mixture at marked positions on the baseline. Dry each spot with cold air.
  4. Place the paper strip in the tank, ensuring the solvent level is 1.0 cm below the baseline.
  5. Allow the solvent to ascend until the front reaches ~12 cm from the origin (approx 45 minutes).
  6. Remove the chromatogram, mark the solvent front promptly with a pencil, and dry in a fume hood.
  7. Hold the dry strip over concentrated ammonia vapor for 1-2 minutes.
  8. Spray evenly with 1% ethanolic DMG solution; observe the immediate appearance of colors.
  9. Measure distances from the origin to the center of each spot and to the solvent front; compute Rf values.

Observations & Expected Results

Before spraying, a faint blue-green tint is visible midway up the Co track. Upon exposure to ammonia and DMG spray: the Ni2+ spot at Rf ≈ 0.08 develops an intense strawberry-red precipitate of [Ni(dmgH)2]; the Co2+ spot at Rf ≈ 0.46 appears as a pale brown/orange zone. The binary mixture clearly resolves into two completely separated spots.

Worked Stoichiometric Calculations

Problem: Solvent front migration distance was 12.5 cm. Ni2+ spot traveled 1.1 cm; Co2+ spot traveled 5.8 cm. Calculate the Rf values and the separation factor (alpha = Rf2 / Rf1).

Working: Rf(Ni2+) = 1.1 / 12.5 = 0.088. Rf(Co2+) = 5.8 / 12.5 = 0.464. Separation factor alpha = Rf(Co2+) / Rf(Ni2+) = 0.464 / 0.088 = 5.27. Complete baseline resolution achieved.

Safety Precautions & Hazard Control

  • Keep the developing chamber tightly covered during chromatography; evaporation of volatile acetone alters eluent composition and causes uneven front migration.
  • Do not allow spots to diffuse wider than 3 mm during sample application.

Waste Disposal Protocol

Used acetone-HCl developer must be neutralized and placed into toxic heavy metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does cobalt form a tetrahedral chloro complex while nickel does not?

A: Cobalt(II) has a d7 electron configuration where the ligand field stabilization energy (LFSE) difference between octahedral and tetrahedral coordination is relatively small (Delta LFSE = 0.27 Delta_o), easily overcome by the gain in entropy and steric relief of 4-coordination. For d8 Ni(II), the octahedral LFSE is high (1.2 Delta_o), strongly disfavoring tetrahedral conversion.

Q: What is the structure of the red nickel-dimethylglyoxime complex?

A: It is a neutral square-planar chelate, bis(dimethylglyoximato)nickel(II), [Ni(dmgH)2], stabilized by two exceptionally strong, symmetrical intramolecular O-H...O hydrogen bonds between adjacent oxime oxygens.

← Back to Experiments Directory