CHEMVEN

Conductometric Determination of Aspirin in Tablets

To assay aspirin tablets conductometrically by titration with NaOH.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To assay aspirin tablets conductometrically by titration with NaOH.

Theoretical Foundations

Aspirin (acetylsalicylic acid, pKa 3.5) titrates as a weak acid: conductance rises gently as the acetylsalicylate salt forms, then steeply with excess OH-. The break gives Ve (1:1 stoichiometry). Conductometry avoids indicator problems in the coloured tablet matrix.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conductivity meter
  • Burette
  • Beaker
  • Stirrer
  • Analytical balance

Chemical Reagents

  • Aspirin tablets
  • NaOH standard (0.1 M)
  • Ethanol (dissolution aid)
  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh powdered tablets (~0.5 g aspirin); dissolve in ethanol-water.
  2. Dilute to ~100 mL in a beaker.
  3. Record conductance with stirring.
  4. Titrate with 0.1 M NaOH in 1 mL steps.
  5. Plot conductance vs volume; find the break.
  6. Calculate mg aspirin per tablet and % of label claim.

Observations & Expected Results

Gentle rise then steep rise; typical assay 95-105% of label.

Worked Stoichiometric Calculations

Problem: Powder (1 tablet) needed 27.8 mL of 0.100 M NaOH. Label 500 mg. Find % assay. (M = 180.16)

Working: Moles = 0.0278 x 0.100 = 2.78 x 10^-3 mol; mass = 2.78 x 10^-3 x 180.16 = 501 mg. % = 501/500 x 100 = 100.2%.

Safety Precautions & Hazard Control

  • Dissolve fully; filter out insoluble excipients if they foul the cell.
  • Titrate promptly to avoid hydrolysis.
  • Constant temperature.

Waste Disposal Protocol

Salicylate solutions to drain.

Viva Voce Oral Defense Questions & Answers

Q: Why 1:1 stoichiometry here?

A: Only the carboxylic-acid proton is titrated under these mild conditions; the ester hydrolyses too slowly to interfere during a quick titration.

Q: Advantage over indicator titration?

A: Tablet excipients and colours can mask the phenolphthalein endpoint; conductance is unaffected.

← Back to Experiments Directory