CHEMVEN

pH-Metric Titration of a Polyprotic Buffer: Carbonate System

To titrate sodium carbonate with HCl pH-metrically, resolving the bicarbonate and carbonic-acid endpoints.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To titrate sodium carbonate with HCl pH-metrically, resolving the bicarbonate and carbonic-acid endpoints.

Theoretical Foundations

CO3(2-) + H+ -> HCO3- (Ve1, ~pH 8.3, phenolphthalein endpoint); HCO3- + H+ -> H2CO3 -> CO2 + H2O (Ve2, ~pH 3.8, methyl orange endpoint). Ve2 = 2 x Ve1. The first derivative shows two peaks; the solution's buffering near Ve1 illustrates the carbonate buffer system of natural waters.

Required Apparatus & Chemicals

Laboratory Apparatus

  • pH meter
  • Burette
  • Beaker
  • Stirrer
  • Pipette

Chemical Reagents

  • Na2CO3 (~0.05 M)
  • HCl standard (0.1 M)
  • Calibration buffers

Step-by-Step Practical Procedure

  1. Calibrate the pH meter.
  2. Pipette 25.0 mL Na2CO3; dilute and stir.
  3. Titrate with 0.1 M HCl recording pH.
  4. Plot pH and dpH/dV vs volume.
  5. Locate Ve1 (~pH 8.3) and Ve2 (~pH 3.8).
  6. Verify Ve2 is about twice Ve1.
  7. Calculate [Na2CO3].

Observations & Expected Results

Two jumps: first near pH 8.3, second near pH 3.8-4.0 with CO2 effervescence.

Worked Stoichiometric Calculations

Problem: Ve1 = 12.4 mL, Ve2 = 24.9 mL of 0.100 M HCl for 25.0 mL sample. Find [Na2CO3].

Working: Moles HCl at Ve2 = 0.0249 x 0.100 = 2.49 x 10^-3 mol (2 H+ per carbonate); moles Na2CO3 = 1.245 x 10^-3 mol. M = 1.245 x 10^-3/0.0250 = 0.0498 M.

Safety Precautions & Hazard Control

  • Stir to release CO2 near Ve2 or the pH drifts.
  • Fine steps near both endpoints.
  • Prepare carbonate solution fresh; it absorbs CO2.

Waste Disposal Protocol

NaCl/CO2 solutions to drain.

Viva Voce Oral Defense Questions & Answers

Q: Write both neutralisation steps.

A: CO3(2-) + H+ -> HCO3-; HCO3- + H+ -> H2O + CO2.

Q: Why do the two indicators differ for the two endpoints?

A: Phenolphthalein (8.3-10) brackets the first endpoint (~pH 8.3); methyl orange (3.1-4.4) brackets the second (~pH 3.8).

Q: Environmental relevance?

A: The carbonate/bicarbonate system buffers natural waters and blood pH.

← Back to Experiments Directory