Electrogravimetry Concept: Copper Determination (Dry-Lab)
To work through an electrogravimetric copper determination as a dry-lab exercise, including current efficiency and deposition completeness.
Theoretical Foundations
In electrogravimetry Cu2+ is reduced onto a weighed Pt cathode at controlled potential; mass gained = mass of Cu (Faraday's law: m = Q M/(n F)). Deposition is complete when the current decays to background. For 0.5 g Cu, Q = 0.5 x 2 x 96485/63.55 = 1518 C; at 2 A this needs ~13 min at 100% efficiency.
Required Apparatus & Chemicals
Laboratory Apparatus
- (Dry-lab) Electrogravimetry data: mass vs time, current vs time
- DC power supply (concept)
- Platinum cathode and anode (concept)
- Analytical balance (concept)
Chemical Reagents
- (Dry-lab) CuSO4/H2SO4 electrolyte (concept)
- (Dry-lab) Platinum electrodes (concept)
- (Dry-lab exercise: current-time data table)
Step-by-Step Practical Procedure
- Tabulate cathode mass versus electrolysis time.
- Plot mass deposited versus time; note the plateau.
- Integrate (or sum) current x time to get total charge Q.
- Compute theoretical mass from Faraday's law.
- Calculate current efficiency = actual/theoretical x 100%.
- State the test for complete deposition.
Observations & Expected Results
Mass plateaus at the expected value; current decays exponentially to a small residual.
Worked Stoichiometric Calculations
Problem: Q passed = 1600 C; cathode gained 0.482 g Cu. Find the current efficiency.
Working: Theoretical m = 1600 x 63.55/(2 x 96485) = 0.527 g. Efficiency = 0.482/0.527 x 100 = 91.5%.
Safety Precautions & Hazard Control
- Dry-lab only; real electrogravimetry uses high currents and acidic baths - supervised lab only.
- In practice, wash and dry the cathode before weighing.
- Control the cathode potential to avoid co-deposition.
Waste Disposal Protocol
No wet waste in the dry-lab version.
Viva Voce Oral Defense Questions & Answers
Q: State Faraday's law for this deposition.
A: m = Q M/(n F): 2 moles of electrons deposit 1 mole (63.55 g) of Cu.
Q: How do you know deposition is complete?
A: The current decays to a constant background and a spot test of the electrolyte shows no Cu2+.
Q: Why control the cathode potential?
A: Too negative a potential co-deposits impurities (e.g. H2 evolution or other metals), spoiling selectivity.