CHEMVEN

Countercurrent Distribution Concept: Craig Apparatus (Dry-Lab)

To simulate Craig countercurrent distribution and find the tube of maximum concentration as a dry-lab exercise.

Level: UniversitySafety: SafeTime: 45 min
Aim of Experiment: To simulate Craig countercurrent distribution and find the tube of maximum concentration as a dry-lab exercise.

Theoretical Foundations

Countercurrent distribution repeatedly partitions a solute between two immiscible solvents; after n transfers the fraction in tube r follows the binomial: f_r = n!/(r!(n-r)!) x (K/(K+1))^r x (1/(K+1))^(n-r), where K is the distribution coefficient (upper/lower). Maximum is at r_max = nK/(K+1). It is the discrete predecessor of chromatography theory.

Required Apparatus & Chemicals

Laboratory Apparatus

  • (Dry-lab) Spreadsheet or calculator
  • Calculator
  • Graph paper
  • Binomial coefficient table

Chemical Reagents

  • (Dry-lab) Two immiscible solvents (concept)
  • (Dry-lab) Solute with given K
  • (Dry-lab exercise: transfer-number worksheet)

Step-by-Step Practical Procedure

  1. Given K = 2.0 and n = 10 transfers, compute f_r for each tube.
  2. Plot the distribution curve.
  3. Find the tube of maximum concentration.
  4. Verify against r_max = nK/(K+1).
  5. Repeat for K = 0.5 and compare the peak positions.
  6. Relate the result to chromatographic elution.

Observations & Expected Results

For K = 2, n = 10, the peak is at tube ~7; for K = 0.5 it is at tube ~3 - higher K means further transfer with the mobile (upper) phase.

Worked Stoichiometric Calculations

Problem: K = 3.0, n = 12. In which tube is the maximum?

Working: r_max = nK/(K+1) = 12 x 3/4 = 9. The maximum concentration is in tube 9.

Safety Precautions & Hazard Control

  • Dry-lab exercise; no chemicals.
  • Note the binomial assumes equal phase volumes and constant K.
  • Real Craig machines are now museum pieces - HPLC replaced them.

Waste Disposal Protocol

No waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is the distribution binomial?

A: Each transfer is an independent partition with probability p = K/(K+1) of moving with the upper phase; n transfers give the binomial distribution.

Q: How does this relate to chromatography?

A: A chromatographic column is the continuous limit of many tiny equilibrations; plate theory grew directly from countercurrent distribution mathematics.

← Back to Experiments Directory