CHEMVEN

Amperometric Titration: Lead with Dichromate (Dry-Lab)

To work through an amperometric titration of Pb2+ with Cr2O7(2-) as a dry-lab exercise and locate the endpoint from the current-volume plot.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To work through an amperometric titration of Pb2+ with Cr2O7(2-) as a dry-lab exercise and locate the endpoint from the current-volume plot.

Theoretical Foundations

In amperometry the current at a fixed applied potential is measured during titration. Holding the rotating Pt electrode at a potential where only Pb2+ reduces: current falls linearly as Pb2+ precipitates (Pb2CrO4), reaching zero at Ve; excess dichromate is not reducible at that potential, so current stays near zero. The intersection of the two lines gives Ve. (Dry-lab: mercury-free treatment.)

Required Apparatus & Chemicals

Laboratory Apparatus

  • (Dry-lab) Titration data table: current vs volume
  • Graph paper / spreadsheet
  • Rotating platinum electrode (concept)
  • DC power supply (concept)
  • Nitrogen purge line (concept)

Chemical Reagents

  • (Dry-lab) Pb2+ sample
  • K2Cr2O7 titrant
  • Supporting electrolyte

Step-by-Step Practical Procedure

  1. Tabulate the given current-volume data.
  2. Plot current versus titrant volume.
  3. Fit straight lines to the falling and flat regions.
  4. Read Ve at their intersection.
  5. Calculate [Pb2+] from the 2:1 Pb:Cr2O7 stoichiometry (2 Pb2+ + Cr2O7(2-) + H2O -> 2 PbCrO4 + 2 H+).
  6. Discuss why the current is zero after Ve.

Observations & Expected Results

Current drops linearly to near zero at Ve, then remains flat; Ve is read precisely at the intersection.

Worked Stoichiometric Calculations

Problem: 25.0 mL Pb2+ sample: Ve = 18.4 mL of 0.0200 M K2Cr2O7. Find [Pb2+].

Working: Moles Cr2O7 = 0.0184 x 0.0200 = 3.68 x 10^-4 mol; moles Pb2+ = 2 x 3.68 x 10^-4 = 7.36 x 10^-4 mol. [Pb2+] = 7.36 x 10^-4/0.0250 = 0.0294 M.

Safety Precautions & Hazard Control

  • Dry-lab exercise; real lead and chromium(VI) compounds are toxic and need supervised handling.
  • In practice, fix the applied potential on the diffusion plateau of Pb2+ only.
  • Deaerate real amperometric cells.

Waste Disposal Protocol

No wet waste in the dry-lab version; real Pb/Cr waste to heavy-metal collection.

Viva Voce Oral Defense Questions & Answers

Q: Why is the current zero after the endpoint?

A: All Pb2+ is precipitated and dichromate is not reduced at the chosen potential, so no electroactive species remains.

Q: Why is amperometry good for precipitation titrations?

A: The endpoint comes from the current, so precipitates that obscure visual indicators cause no problem.

← Back to Experiments Directory