Ammonia Gas-Sensing Electrode: Kjeldahl Nitrogen Finish
To determine nitrogen in a food sample by Kjeldahl digestion, distillation and ammonia gas-sensing electrode measurement.
Theoretical Foundations
Kjeldahl digestion converts organic N to NH4+; making the digest alkaline liberates NH3, which diffuses across the gas-sensing electrode's hydrophobic membrane into an internal NH4Cl filling solution, changing its pH. The glass electrode inside senses this pH shift: E = const - 0.05916 log[NH3]. Calibration with NH4Cl standards gives the ammonia, hence % N (protein = N x 6.25).
Required Apparatus & Chemicals
Laboratory Apparatus
- Kjeldahl digestion unit
- Distillation apparatus
- Ammonia gas-sensing electrode + mV meter
- Analytical balance
Chemical Reagents
- Food sample (e.g. milk powder)
- Conc. H2SO4 + catalyst (digestion)
- NaOH (10 M, for distillation)
- NH4Cl standards
- Boric acid receiver (optional cross-check)
Step-by-Step Practical Procedure
- Digest ~1 g sample in conc. H2SO4 with catalyst until clear.
- Cool, dilute, and transfer to the distillation flask.
- Add excess 10 M NaOH and steam-distil NH3 into a receiver.
- Calibrate the ammonia electrode with NH4Cl standards made alkaline.
- Make the distillate alkaline and measure its potential.
- Read [NH3] from the calibration and calculate % N and % protein.
Observations & Expected Results
Electrode slope ~-58 mV/decade; typical milk powder gives ~5.5% N (~34% protein).
Worked Stoichiometric Calculations
Problem: 1.002 g sample gave distillate reading equivalent to 52.0 mg NH3. Calculate % N and % protein.
Working: N mass = 52.0 x 14.01/17.03 = 42.8 mg. % N = 42.8/1002 x 100 = 4.27%. Protein = 4.27 x 6.25 = 26.7%.
Safety Precautions & Hazard Control
- Conc. H2SO4 digestion: fume hood, face protection.
- 10 M NaOH is highly caustic.
- Keep the gas-sensing membrane intact; never touch it.
Waste Disposal Protocol
Acidic digest waste neutralised before disposal; distillation residues to drain with water.
Viva Voce Oral Defense Questions & Answers
Q: How does the gas-sensing electrode work?
A: NH3 diffuses through a gas-permeable membrane into an internal electrolyte, shifting its pH; an internal glass electrode measures that pH shift, which is proportional to log[NH3].
Q: Why is the factor 6.25 used?
A: Average proteins contain ~16% nitrogen by mass, so protein mass = N mass x 100/16 = N x 6.25.
Q: Why distil instead of measuring the digest directly?
A: Distillation separates volatile NH3 from the complex digest matrix, which would foul or poison the electrode.