CHEMVEN

Potentiometric Precipitation Titration: Iodide vs AgNO3 (Fajans Comparison)

To titrate iodide with AgNO3 potentiometrically and compare the endpoint with the Fajans adsorption-indicator method.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To titrate iodide with AgNO3 potentiometrically and compare the endpoint with the Fajans adsorption-indicator method.

Theoretical Foundations

Ag+ + I- -> AgI(s) (Ksp = 8.3 x 10^-17). The silver electrode senses the huge [Ag+] jump at Ve. In parallel, the Fajans titration uses eosin: before Ve the AgI colloid adsorbs I- (yellow), after Ve it adsorbs Ag+ and then the eosin anion, turning the precipitate pink. Comparing Ve values tests the indicator's accuracy.

Required Apparatus & Chemicals

Laboratory Apparatus

  • mV meter
  • Silver + reference electrodes
  • Burette
  • Conical flasks
  • White tile

Chemical Reagents

  • KI (~0.05 M)
  • AgNO3 standard (0.05 M)
  • Eosin indicator (Fajans)
  • Dextrin (protective colloid, optional)

Step-by-Step Practical Procedure

  1. Pipette 25.0 mL KI; titrate potentiometrically with AgNO3 to get Ve(pot).
  2. Repeat the titration in a flask with 2 drops of eosin indicator.
  3. Note the volume where the precipitate turns pink (Ve(Fajans)).
  4. Compare the two endpoints and compute the indicator error.
  5. Calculate [I-] from the potentiometric Ve.

Observations & Expected Results

The potentiometric jump is very large (~400 mV, reflecting the tiny Ksp); the eosin endpoint typically agrees within 0.5-1%.

Worked Stoichiometric Calculations

Problem: Ve(pot) = 24.9 mL, Ve(Fajans) = 25.1 mL of 0.0500 M AgNO3 for 25.0 mL sample. Give the indicator error and [I-].

Working: Indicator error = 25.1 - 24.9 = +0.2 mL (+0.8%). [I-] = 0.0249 x 0.0500/0.0250 = 0.0498 M.

Safety Precautions & Hazard Control

  • Protect AgNO3 from light.
  • Shake the Fajans flask well near the endpoint.
  • Keep AgI waste contained (light-sensitive).

Waste Disposal Protocol

Silver halide waste to heavy-metal collection.

Viva Voce Oral Defense Questions & Answers

Q: Why is the potentiometric jump so large for iodide?

A: AgI has an extremely small Ksp, so [Ag+] changes by many orders of magnitude at the endpoint, amplified logarithmically into a huge potential jump.

Q: Explain the Fajans colour change.

A: Before Ve the colloidal AgI adsorbs I- and repels eosin (stays yellow); after Ve it adsorbs Ag+, attracting the eosin anion, which turns pink on adsorption.

← Back to Experiments Directory