CHEMVEN

pH-Metric Determination of Vitamin C (Ascorbic Acid)

To assay ascorbic acid in vitamin C tablets by pH-metric titration with NaOH.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To assay ascorbic acid in vitamin C tablets by pH-metric titration with NaOH.

Theoretical Foundations

Ascorbic acid (pKa1 = 4.17, pKa2 = 11.6) behaves as a monoprotic acid in the first titration jump (endpoint ~pH 8). Titrating pH-metrically with standard NaOH and locating Ve from dpH/dV gives moles of ascorbic acid (1:1). Mass = moles x 176.12 g/mol; compare with the label claim.

Required Apparatus & Chemicals

Laboratory Apparatus

  • pH meter
  • Burette
  • Beaker
  • Analytical balance
  • Stirrer

Chemical Reagents

  • Vitamin C tablets
  • NaOH standard (0.1 M)
  • Calibration buffers
  • Distilled water (freshly boiled)

Step-by-Step Practical Procedure

  1. Weigh and powder tablets equivalent to ~0.2 g ascorbic acid.
  2. Dissolve in freshly boiled, cooled distilled water.
  3. Titrate pH-metrically with 0.1 M NaOH.
  4. Locate Ve from the first-derivative peak (~pH 8).
  5. Calculate mg ascorbic acid per tablet.
  6. Compute % of label claim.

Observations & Expected Results

One clear jump near pH 8; typical tablets assay 95-105% of the labelled 500 mg or 1000 mg.

Worked Stoichiometric Calculations

Problem: Powder (1 tablet) needed 28.6 mL of 0.100 M NaOH. Label claim 500 mg. Find % assay. (M = 176.12)

Working: Moles = 0.0286 x 0.100 = 2.86 x 10^-3 mol. Mass = 2.86 x 10^-3 x 176.12 = 504 mg. % = 504/500 x 100 = 101%.

Safety Precautions & Hazard Control

  • Use freshly boiled water; dissolved O2 and CO2 degrade/perturb ascorbic acid.
  • Titrate promptly; ascorbic acid oxidises in air.
  • Only the first endpoint is used.

Waste Disposal Protocol

Ascorbate solutions to drain.

Viva Voce Oral Defense Questions & Answers

Q: Why is only the first endpoint used?

A: pKa2 (11.6) is too weak to give a usable jump; the first neutralisation (pKa1 4.17) gives a clean endpoint near pH 8.

Q: Why freshly boiled distilled water?

A: To remove dissolved oxygen (which oxidises ascorbate) and CO2 (which would consume NaOH).

← Back to Experiments Directory