CHEMVEN

Redox Potential Ladder: Ranking Oxidising Agents Potentiometrically

To rank MnO4-, Cr2O7(2-) and Fe3+ as oxidising agents by measuring their solution potentials with a Pt electrode.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To rank MnO4-, Cr2O7(2-) and Fe3+ as oxidising agents by measuring their solution potentials with a Pt electrode.

Theoretical Foundations

The measured potential of a redox couple at known concentration ratio gives its formal potential via the Nernst equation. Comparing formal potentials in the same medium (1 M H2SO4) ranks oxidising strength: higher E0 means a stronger oxidant. Expected order: MnO4-/Mn2+ (1.51 V) > Cr2O7(2-)/Cr3+ (1.33 V) > Fe3+/Fe2+ (0.77 V).

Required Apparatus & Chemicals

Laboratory Apparatus

  • mV meter
  • Pt electrode
  • Reference electrode
  • Beakers

Chemical Reagents

  • KMnO4 (0.02 M)
  • K2Cr2O7 (0.02 M)
  • FeCl3/FeSO4 mixture
  • 1 M H2SO4

Step-by-Step Practical Procedure

  1. Prepare each couple in 1 M H2SO4 with oxidised and reduced forms at equal molarity.
  2. Measure the potential of each solution vs the reference electrode.
  3. Convert readings to the SHE scale (add 0.244 V for SCE).
  4. Rank the three couples by measured formal potential.
  5. Compare the ranking and values with literature E0 data.
  6. Test the ranking chemically: add Fe2+ to acidified permanganate and note decolourisation.

Observations & Expected Results

Measured potentials cluster near 1.5 V (permanganate), 1.3 V (dichromate) and 0.77 V (iron); permanganate oxidises Fe2+ instantly with loss of purple colour.

Worked Stoichiometric Calculations

Problem: The Fe3+/Fe2+ (1:1) solution reads 0.53 V vs SCE. What is E vs SHE?

Working: E(SHE) = 0.53 + 0.244 = 0.774 V, matching E0(Fe3+/Fe2+) = 0.77 V since [ox] = [red].

Safety Precautions & Hazard Control

  • KMnO4 stains skin and is a strong oxidant; wear gloves.
  • Keep dichromate waste separate (Cr(VI) is toxic).
  • Clean the Pt electrode between measurements.

Waste Disposal Protocol

Chromium waste to Cr(VI) collection; permanganate reduced with sulfite before disposal.

Viva Voce Oral Defense Questions & Answers

Q: Why measure at a 1:1 ox:red ratio?

A: Then log([ox]/[red]) = 0 and the measured potential equals the formal potential E0' directly.

Q: Why must the medium be the same for all couples?

A: Formal potentials depend on pH and complexation; only the same medium makes the ranking meaningful.

← Back to Experiments Directory