CHEMVEN

Verifying the Nernst Equation: Cu2+/Cu Concentration Cell

To verify the Nernst equation by measuring the EMF of copper concentration cells at 25 C.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To verify the Nernst equation by measuring the EMF of copper concentration cells at 25 C.

Theoretical Foundations

For Cu2+ + 2e- -> Cu, E_cell = (0.05916/2) log([Cu2+]_cathode/[Cu2+]_anode) = 0.02958 log(ratio) at 25 C. A tenfold concentration ratio should give 29.6 mV. Measuring cells with 10:1 and 100:1 ratios tests the logarithmic dependence and the 2-electron slope.

Required Apparatus & Chemicals

Laboratory Apparatus

  • High-impedance voltmeter
  • Two copper electrodes
  • Salt bridge (KNO3 agar)
  • Beakers
  • Volumetric glassware
  • Thermostat

Chemical Reagents

  • CuSO4 solutions: 1.0 M, 0.1 M, 0.01 M
  • KNO3 (salt bridge electrolyte)
  • Agar (salt bridge gel)
  • Dilute nitric acid (electrode cleaning)

Step-by-Step Practical Procedure

  1. Clean copper electrodes with dilute nitric acid, rinse and dry.
  2. Set up a cell: Cu | 0.1 M CuSO4 || 1.0 M CuSO4 | Cu with salt bridge.
  3. Thermostat at 25 C and record the EMF.
  4. Repeat for the 0.01 M vs 1.0 M pair (100:1).
  5. Calculate theoretical EMFs from the Nernst equation.
  6. Compare measured vs theoretical values and compute % error.

Observations & Expected Results

Measured EMFs are typically within 1-2 mV of 29.6 mV (10:1) and 59.2 mV (100:1).

Worked Stoichiometric Calculations

Problem: Measured EMF for the 100:1 cell is 58.5 mV. What is the % error versus theory?

Working: Theory = 0.02958 x log(100) = 0.05916 V = 59.2 mV. % error = (59.2-58.5)/59.2 x 100 = 1.2%.

Safety Precautions & Hazard Control

  • Use a high-impedance voltmeter so negligible current flows.
  • Keep temperature at 25.0 C.
  • Prepare the salt bridge fresh to avoid junction drift.

Waste Disposal Protocol

CuSO4 solutions to heavy-metal aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: Write the Nernst equation for this cell and evaluate the 10:1 EMF.

A: E = (0.05916/2) log(10/1) = 0.02958 x 1 = 29.6 mV at 25 C.

Q: Why must the voltmeter have high impedance?

A: So that essentially no current flows; current would polarise the electrodes and the measured EMF would drop below the equilibrium value.

Q: Why is a salt bridge needed?

A: It completes the circuit while preventing the two solutions from mixing, keeping the concentration ratio defined.