Conductometric Titration: Strong Acid vs Strong Base
To titrate HCl with NaOH conductometrically and locate the endpoint at the minimum of the conductance-volume curve.
Theoretical Foundations
Conductance depends on the number and mobility of ions. As NaOH is added to HCl, highly mobile H+ (350 S cm2/mol) is replaced by less mobile Na+ (50 S cm2/mol), so conductance falls linearly. After the equivalence point, excess OH- (198 S cm2/mol) raises conductance steeply. The two straight lines intersect at the endpoint; the V-shape is characteristic of strong acid-strong base titrations.
Required Apparatus & Chemicals
Laboratory Apparatus
- Conductivity meter with dip cell
- Burette
- Beaker
- Magnetic stirrer
- Pipette
Chemical Reagents
- HCl (~0.05 M)
- NaOH standard (0.1 M)
- Distilled water
Step-by-Step Practical Procedure
- Pipette 25.0 mL HCl into a beaker and dilute to ~100 mL (dilution keeps the cell covered and linear).
- Immerse the conductivity cell and record the initial conductance with stirring.
- Add NaOH in 1 mL portions, recording conductance after each addition.
- Continue at least 5 mL past the expected endpoint.
- Plot conductance versus volume of NaOH.
- Draw the two best-fit straight lines and read their intersection as Ve.
- Calculate the HCl molarity.
Observations & Expected Results
Conductance falls linearly to a sharp minimum then rises steeply; the intersection gives Ve with excellent precision even in coloured solutions.
Worked Stoichiometric Calculations
Problem: 25.0 mL HCl gave Ve = 12.3 mL of 0.100 M NaOH. Calculate [HCl].
Working: Moles NaOH = 0.0123 x 0.100 = 1.23 x 10^-3 mol = moles HCl. [HCl] = 1.23 x 10^-3/0.0250 = 0.0492 M.
Safety Precautions & Hazard Control
- Keep the cell fully immersed at constant depth; position affects the reading.
- Maintain constant temperature: conductance rises ~2% per degree C.
- Rinse the cell with distilled water before use.
Waste Disposal Protocol
Dilute NaCl solutions to drain.
Viva Voce Oral Defense Questions & Answers
Q: Why does conductance fall before the endpoint?
A: Fast H+ ions are replaced by slower Na+ ions as neutralisation proceeds, lowering total ionic conductance.
Q: Why does it rise steeply after the endpoint?
A: Excess OH-, which has very high ionic mobility, accumulates in solution.
Q: Name an advantage of conductometry over indicators.
A: It works in coloured or turbid solutions where a colour change cannot be seen, and needs no indicator.