CHEMVEN

Ion-Exchange Determination of Total Cation Load

To determine the total exchangeable cation content of a water sample by passing it through a H+-form resin and titrating the liberated acid.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To determine the total exchangeable cation content of a water sample by passing it through a H+-form resin and titrating the liberated acid.

Theoretical Foundations

A cation exchanger in the H+ form converts every retained cation into an equivalent amount of H+: R-SO3H + Na+ -> R-SO3Na + H+. The liberated strong acid is titrated with standard NaOH, so the titre measures total cation equivalents regardless of which cations were present. Regeneration with HCl restores the H+ form.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Cation-exchange column (H+ form)
  • Burette
  • Conical flasks
  • Measuring cylinder

Chemical Reagents

  • Water sample
  • Standard NaOH (0.02 M)
  • Phenolphthalein indicator
  • HCl (1 M) for regeneration

Step-by-Step Practical Procedure

  1. Convert the resin to H+ form with 1 M HCl and rinse until the effluent is neutral.
  2. Pass 100 mL of sample slowly through the column; collect the effluent.
  3. Titrate the effluent with 0.02 M NaOH to the phenolphthalein endpoint.
  4. Repeat with a second 100 mL portion for duplicate results.
  5. Calculate total cations as milliequivalents per litre.
  6. Regenerate the column with HCl and rinse before storage.

Observations & Expected Results

The effluent is acidic (pH 2-3) even for neutral samples; typical titres are a few mL of 0.02 M NaOH per 100 mL of tap water.

Worked Stoichiometric Calculations

Problem: 100 mL of sample effluent needed 8.4 mL of 0.02 M NaOH. Express total cations in meq/L.

Working: Equivalents of H+ = 8.4 mL x 0.02 mmol/mL = 0.168 mmol = 0.168 meq per 100 mL. Per litre: 0.168 x 10 = 1.68 meq/L.

Safety Precautions & Hazard Control

  • Rinse the column free of regenerant acid before loading the sample, or the blank will be high.
  • Maintain a slow, steady flow for complete exchange.
  • Standardise the NaOH before use.

Waste Disposal Protocol

Neutralised titration waste to drain; HCl regenerant neutralised before disposal.

Viva Voce Oral Defense Questions & Answers

Q: Why does this method measure total cations irrespective of identity?

A: Every cation equivalent displaces exactly one equivalent of H+, so the acid titrated equals total cation equivalents by stoichiometry.

Q: Write the exchange reaction for Mg2+.

A: 2 R-SO3H + Mg2+ -> (R-SO3)2Mg + 2 H+.