Separation of Metal Ions by Paper Chromatography
To separate Cu2+, Fe3+ and Ni2+ on paper and identify them with selective spray reagents.
Theoretical Foundations
Metal ions separate on paper by partition and by complex formation with the mobile phase (e.g. chloride complexes in HCl-containing solvents). Each ion has a characteristic Rf; selective chromogenic reagents then locate them: Fe3+ with thiocyanate (blood-red), Cu2+ with rubeanic acid or ammonia (blue), Ni2+ with dimethylglyoxime (red).
Required Apparatus & Chemicals
Laboratory Apparatus
- Filter paper strips
- Developing chamber
- Spray bottles
- Capillary tubes
Chemical Reagents
- CuSO4, FeCl3, NiSO4 solutions (0.1 M)
- Unknown cation mixture
- Mobile phase: acetone : conc. HCl : water 87:8:5 (use dilute HCl)
- KSCN solution
- Dimethylglyoxime in ethanol
- Ammonia solution
Step-by-Step Practical Procedure
- Spot the three standards and the unknown on the baseline.
- Develop in the acetone-HCl-water system until the front is near the top.
- Dry the chromatogram thoroughly to remove HCl.
- Cut the strip into sections or spray selectively: KSCN for Fe3+ (red), dimethylglyoxime + ammonia for Ni2+ (red), ammonia for Cu2+ (deep blue).
- Measure Rf of each identified band.
- Identify the cations in the unknown by Rf and colour reactions.
Observations & Expected Results
Typical order: Fe3+ (as chloro-complex, high Rf, red with SCN-) > Cu2+ (intermediate, blue with NH3) > Ni2+ (lower Rf, red with DMG).
Worked Stoichiometric Calculations
Problem: Fe3+ travelled 7.2 cm with a 9.0 cm front. Calculate its Rf.
Working: Rf = 7.2/9.0 = 0.80.
Safety Precautions & Hazard Control
- The mobile phase contains HCl: prepare and use in a fume hood.
- Dry off all HCl before spraying or the reagents will be affected.
- Wear gloves when handling metal salt solutions.
Waste Disposal Protocol
Acidic solvent to neutralised aqueous waste; metal-stained paper to heavy-metal solid waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is HCl included in the mobile phase?
A: Chloride forms anionic chloro-complexes (e.g. FeCl4-) that partition into the organic-rich mobile phase, greatly improving Fe3+ mobility and separation.
Q: Why is dimethylglyoxime selective for nickel?
A: It forms a characteristic red chelate specifically with Ni2+ under ammoniacal conditions.