Ion-Exchange Chromatography: Softening Hard Water

To soften a hard-water sample with a cation-exchange resin in the sodium form and determine the hardness removed by EDTA titration.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To soften a hard-water sample with a cation-exchange resin in the sodium form and determine the hardness removed by EDTA titration.

Theoretical Foundations

A sulfonated polystyrene cation exchanger in Na+ form exchanges 2 R-SO3Na + Ca2+ -> (R-SO3)2Ca + 2 Na+. Calcium and magnesium are retained while sodium passes through, so total hardness drops. The resin is regenerated with brine, reversing the equilibrium by mass action. Hardness before and after is measured by EDTA complexometric titration with Eriochrome Black T.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Glass column with cation-exchange resin (Na+ form)
  • Burette (50 mL)
  • Conical flasks
  • Measuring cylinders
  • pH paper

Chemical Reagents

  • Hard water sample (or prepared CaCl2/MgSO4 solution)
  • EDTA standard solution (0.01 M)
  • Eriochrome Black T indicator
  • Ammonia buffer pH 10
  • NaCl (regeneration brine, 10%)

Step-by-Step Practical Procedure

  1. Condition the resin column by passing distilled water until the effluent is neutral.
  2. Titrate 50 mL of the raw water with 0.01 M EDTA using Eriochrome Black T to find initial hardness.
  3. Pass 200 mL of the sample slowly through the resin column and collect the effluent.
  4. Titrate the treated effluent the same way to find residual hardness.
  5. Calculate hardness removed in mg/L as CaCO3.
  6. Regenerate the column with 10% NaCl and rinse to neutral before storage.

Observations & Expected Results

Raw hard water typically needs 10-20 mL of 0.01 M EDTA per 50 mL sample; after exchange the titre falls to near zero, showing most Ca2+/Mg2+ were removed.

Worked Stoichiometric Calculations

Problem: 50 mL of raw water needed 14.0 mL of 0.01 M EDTA; after treatment it needed 1.2 mL. Calculate hardness removed as mg/L CaCO3.

Working: Hardness (mg/L as CaCO3) = V_EDTA x M_EDTA x 100000 / V_sample. Removed titre = 14.0 - 1.2 = 12.8 mL. Removed = 12.8 x 0.01 x 100000 / 50 = 256 mg/L as CaCO3.

Safety Precautions & Hazard Control

  • Do not let the resin bed run dry; air bubbles channel the flow.
  • Pass the sample slowly (a few mL/min) so exchange reaches equilibrium.
  • Regenerate before the resin is exhausted or hardness will break through.

Waste Disposal Protocol

EDTA titration waste can go down the drain with water; brine regenerant to aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: Write the exchange reaction for calcium removal.

A: 2 R-SO3Na + Ca2+ -> (R-SO3)2Ca + 2 Na+.

Q: Why does brine regenerate the resin?

A: High Na+ concentration drives the equilibrium backwards by mass action, displacing Ca2+ and restoring the sodium form.

Q: Why is the titration done at pH 10?

A: EDTA complexes Ca2+/Mg2+ quantitatively at pH 10 and Eriochrome Black T shows its sharp wine-red to blue endpoint there.