Nernst Equation
Cell potential under non-standard conditions: E = E° − (RT/nF)·lnQ.
Overview & Foundations
Connect a fresh Daniell cell to a voltmeter and it reads close to its standard value, 1.10 V. Leave it running and the reading drifts downwards, slowly at first and then towards zero as the cell dies — yet nothing in the standard electrode potential table has changed. Start instead with the zinc side deliberately dilute and the copper side concentrated, and the same cell reads higher than 1.10 V, as the first worked example below shows: with [Zn²⁺] = 0.10 mol/L and [Cu²⁺] = 1.0 mol/L it gives 1.13 V. Standard potentials describe one particular set of concentrations. A real cell lives at other concentrations, and it needs an equation that follows the voltage as the concentrations move. That equation is Nernst's.
Walther Nernst derived it in 1889 by linking the electrical work a cell can do to the free energy of its reaction. The free energy under non-standard conditions is ΔG = ΔG° + RT ln Q, where Q is the reaction quotient — products over reactants, each raised to its stoichiometric power, with pure solids and liquids omitted. Since the electrical work gives ΔG = −nFE and ΔG° = −nFE°, substitution and a change of sign give the Nernst equation, E = E° − (RT/nF) ln Q. Every symbol earns its place: n is the number of moles of electrons transferred in the balanced cell reaction, F is the Faraday constant, R is the gas constant, T is the temperature in kelvin, and the logarithm is the natural logarithm in this form. The equation is not an empirical correction; it is thermodynamics read through a voltmeter.
At 298 K the constants combine into a number worth memorising. RT/F evaluates so that, after converting the natural logarithm to base ten, the equation becomes E = E° − (0.0592/n) log Q, with 0.0592 V often written 0.05916 V. The meaning is immediate: for each tenfold change in Q, the EMF changes by 0.0592/n volts. A one-electron reaction is the most sensitive, shifting by about 59 mV per decade; the two-electron Daniell reaction shifts by about 29.6 mV per decade; and a reaction with a large n barely notices concentration changes at all. This slope is also why the sign in front of the log term matters so much — Q greater than 1 must lower E, because a system already rich in products has less driving force left, while Q less than 1 must raise it.
Applying the equation reliably is a matter of routine rather than inspiration. Write the balanced cell reaction first, because Q and n both come from it and a wrong equation guarantees a wrong answer. Build Q with aqueous ions and gas pressures in their places and leave out pure solids and pure liquids — solid zinc and solid copper do not appear in the Daniell quotient, which is simply Q = [Zn²⁺]/[Cu²⁺]. Take the standard EMF from reduction potentials as E°cell = E°cathode − E°anode, without multiplying potentials by coefficients. Then substitute, keeping the base-ten form with 0.0592 at 298 K strictly separate from the natural-log form with RT/nF; mixing the two logarithm bases is the classic way to lose an otherwise correct calculation.
The equation also runs in reverse, from a measured voltage back to chemistry. At equilibrium a cell can do no work, so E = 0 and the Nernst equation collapses to a relationship between standard potential and equilibrium constant, log K = nE°/0.0592 at 298 K — a modest standard potential implies an astronomically product-favoured reaction, which is why EMF measurements determine equilibrium constants that are far too large or small to measure directly. For a single electrode the same logic gives the potential of one half-cell at non-standard concentrations, the form used for the hydrogen electrode example below. There, for 2H⁺ + 2e⁻ → H₂ with hydrogen at 1 bar, the equation reduces to E = −0.0592 × pH, so each pH unit moves the potential by exactly one Nernst slope — the principle on which the glass pH electrode and every pH meter are built, shifting by 59.2 mV per pH unit at 25 °C.
That reach is why the equation appears far beyond textbook cells. Battery gauges infer state of charge from how far the EMF has drifted from its fresh value. Corrosion scientists use potentials at real, dilute ion concentrations — not the unrealistic 1 mol/L standard state — to judge whether a metal is actually at risk in seawater or soil. Ion-selective electrodes in medicine and environmental analysis turn the Nernst slope into a measuring instrument for sodium, potassium, calcium and other ions, reporting concentration as a voltage. In every case the reasoning is identical: write Q honestly for the conditions in front of you, respect n and the temperature, and let the equation translate between concentration, free energy and volts.
Core Chemical Concepts
- The Nernst equation gives a cell's EMF at non-standard concentrations
- E = E° − (RT/nF) ln Q in general; E = E° − (0.0592/n) log Q at 298 K
- At 298 K the slope is 0.0592/n volts per tenfold change in Q
- Q is the reaction quotient — pure solids and liquids are omitted
- Q > 1 lowers E; Q < 1 raises E; at equilibrium E = 0 and Q = K
- A pH electrode shifts by 59.2 mV per pH unit at 25 °C
Governing Formulas & Laws
Nernst equation in its general, natural-logarithm formPractical base-ten form at 25 °C — do not mix it with the ln formEquilibrium constant from standard EMF, obtained by setting E = 0Hydrogen electrode at 1 bar H₂ — the basis of the pH meterWorked Numerical Examples
Industrial & Laboratory Applications
- pH meters and glass electrodes, working at 59.2 mV per pH unit
- Battery state-of-charge estimation from the drifting EMF
- Ion-selective electrodes for medical and environmental analysis
- Corrosion prediction using potentials at real, dilute concentrations
Common Student Misconceptions
Everyday Life & Real-World Relevance
- Fresh cell: Q small, E near or above E°; dead cell: Q = K, E = 0
- Nernst slope at 298 K: 0.0592/n V per tenfold change in Q
- Routine: balance the reaction → write Q → find n → substitute carefully
- log K = nE°/0.0592 links EMF measurements to equilibrium constants
- pH is a Nernst measurement: 59.2 mV per pH unit at 25 °C
Practice & Review Questions
Scholarly Literature & References
- Atkins & de Paula, Atkins' Physical Chemistry
- Skoog, West, Holler & Crouch, Fundamentals of Analytical Chemistry
- Nernst, W. (1889). Die elektromotorische Wirksamkeit der Ionen. Zeitschrift für physikalische Chemie, 4, 129–181.